The model 1000C series is an upgrade to the model 1000/1000A/1000B series. The instrument allows eight independent cells, simultaneous or sequential measurements, fast waveform generation and data acquisition speed (1 MHz @ 16-bit), and easy software update using flash memory.
Many electrochemical techniques are available in the 1000C series, including cyclic voltammetry and amperometric i-t measurements, with all eight channels available (except for open circuit potential measurements). The parameters for all channels must be set before running an experiment; you cannot alter parameter settings during experiments. During a run, you can toggle between single and multi-data set display (parallel or overlay plots). After a run, you can choose data from any channel for parallel or overlay plotting.
The instrument can be controlled by an external PC running Windows 98 or higher. It is easy to install and use. The instrument connects to your PC using USB (default) or serial port connectivity; no plug-in card or other hardware is required on the PC side. The commands, parameters, and options have been written using terminology that most chemists are familiar with. A customizable toolbar allows quick access to the most commonly used commands. A comprehensive help system provides context-sensitive information from each dialog box.
The instrument provides many powerful functions, such as straightforward file handling, extensive experimental control, flexible graphics, various data analyses, and efficient digital simulation. Additional features include macro commands, working electrode conditioning, color, legend and font selection, data interpolation, visual baseline correction, data point removal, visual data point modification, signal averaging, Fourier spectrum, and a convenient technique-specific electrochemical equation viewer. The maximum data length is 128K – 8192K points (selectable) if real-time data transfer is allowed.
8-Channel potentiostat (8 independent cells or a multi-working electrode cell) Potential range (all channels): ±10 V Compliance voltage: ±12 V Current range (each channel): 10 mA Reference electrode input impedance: 1x1012 ohm Sensitivity scale: 1x10-9 - 0.001 A/V in 7 ranges Input bias current: < 50 pA Current measurement resolution: < 1 pA Data acquisition: 16 bit @ 1 MHz maximum CV and LSV scan rate:
CC and CA pulse width: 0.0001 to 1000 s CA and CC sample interval:
|
DPV and NPV pulse width: 0.001 to 10 s SWV frequency:
ACV frequency:
SHACV frequency:
i-t sample interval:
Current low-pass filters Current analog output Cell control: purge, stir, knock Maximum data length: 128K - 4096K selectable Chassis dimensions: 14.25”(W) x 9.25 ”(D) x 4.75”(H) |
Overlay plot of 8 channel i-t curve with a different potential setting for each channel
Overlay plot of 8 channel SWV with all eight channel potentials scanned simultanousely